Skip to main content

Control

Supervised remote control.

Monitor first; control when you choose to. Control is opt-in, commissioned and fully audited, for compatible equipment.

01 / What you can control

Set it, switch it, survey it.

  • DC set-points.

    Rectifier DC voltage and DC current set-points.

  • On and off.

    Static on/off of the rectifier output.

  • Interruption cycles.

    Cyclic on/off with your own on and off times, for instant-off potential surveys. A cycle ends by itself and leaves the output on.

  • GPS-synchronized interruption.

    With the optional Argus GPS module.

  • Reporting interval.

    Transmissions per day, with an estimate of your monthly messaging cost before you commit.

  • Any connected equipment.

    Set-points, switching and writable registers through Argus or Modbus, limited to the parameters commissioned as writable.

02 / The lifecycle

Send a command. Watch it land.

Set the DC output, switch a unit on or off, or run interruption cycles and read the instant-off potential. GPS-synchronized with the optional Argus GPS module.

  1. Pending
  2. Sending
  3. Awaiting acknowledgement
  4. Applied

Or Failed, with the reason.

Applied only when the unit confirms it, or a Modbus read-back matches the value you asked for.

See how control works

Illustration of an interruption cycle: the rectifier switches on and off, and the pipe-to-soil potential is read at the instant of switching off.RectifierONOFFPipe-to-soil potential−850 mV criterionInstant-off
Illustration, not measured data.
  • Limits are checked on the server, not in the browser.
  • Only people with control permission, for that station, can send.
  • Confirmation where the command requires it.
  • Every command is written to the audit log.

03 / Guardrails

Eleven guardrails on every command.

  1. Permission and station scope.

    Only people with control permission, on stations in their scope, can send.

  2. Two-step confirmation.

    Bound to that person and those exact values, and usable once.

  3. Bounds checked twice.

    At request time and again just before sending. Values outside the unit's limits are refused.

  4. Applied only when confirmed.

    Applied only when the unit confirms it, or a Modbus read-back matches the value you asked for.

  5. One command in flight.

    A newer request supersedes older ones, and nothing is replayed after a restart or restore.

  6. Rate-limited.

    More strictly than ordinary actions.

  7. Fully audited.

    Every request, confirmation, cancellation and outcome, with person, time, values and result.

  8. Alarms on control failure.

    Set-point deviation, a failure to switch, or a command not carried out.

  9. Supervisory use only.

    Commands travel over cellular links, so Hermes is not built for functions that need a fixed response time.

  10. Advice stays advice.

    Analytics never send a command.

  11. Licences never disable monitoring.

    Control and analytics depend on your plan; monitoring and safety status never do.

04 / Speed

As fast as the link allows.

Real time over MQTT, Ethernet, Wi-Fi or a virtual Cyclops. Every one to five minutes over the Cyclops serial link.

Built on NACE criteria: the −850 mV protection criterion and instant-off.

See it running before you talk to anyone.