Industrial SCADA
SCADA for the power behind infrastructure.
In the cloud, on your servers, or on a PC with no internet.
Proudly Made in Pakistan ๐ต๐ฐ

01 / The field
One platform for every power asset on the network.
What Hermes reads, and which commands a unit accepts, come from its model profile. Adding a model is configuration, not a software release.
- 01
Cathodic protection
Monitor and control.
Through Argus and Cyclops, or Modbus TCP/RTU direct.
Typical parameters- Pipe-to-Soil Potential (PSP)
- Rectifier DC Output Voltage
- Rectifier DC Output Current
- AC Input Voltage
- DC Side Status
- AC Side Status
- AC Input Current
Seven or more, depending on the CP configuration: a TEG unit, solar or a GPS interrupter brings its own parameters.
Configurations vary. We can provide any parameter you need.
- 02
DC power supplies and rectifiers
Monitor and control.
Through Argus and Cyclops, or Modbus TCP/RTU direct.
Typical parameters- DC V
- DC A
- AC V
- AC A
- DC Fuse Status
- AC Fuse Status
- Power Analyzer
Configurations vary. We can provide any parameter you need.
- 03
Battery chargers and DC systems
Monitor and control.
Through Argus and Cyclops, or Modbus TCP/RTU direct.
Typical parameters- AC V
- AC A
- DC Aux. V
- DC Batt. V
- DC Aux. Load Current
- DC Charging-Discharging Current
- Alarms and Indications
Configurations vary. We can provide any parameter you need.
- 04
Defence and aviation ground support
Monitor and control.
Through Argus and Cyclops, or Modbus TCP/RTU direct.
Typical parameters- DC V
- DC A
- Input AC V
- Input AC A
- Output AC V
- Output AC A
- Input Frequency
- Output Frequency
- Uptime
Configurations vary. We can provide any parameter you need.
- 05
Voltage regulation and power conditioning
Monitor and control.
Through Argus and Cyclops, or Modbus TCP/RTU direct.
Typical parameters- Output Current โ Phase A/B/C
- Input Voltage โ Phase A/B/C
- Output Voltage โ Phase A/B/C
- Input Current โ Phase A/B/C
- Ambient Temperature
- Over-Voltage Fault
- Under-Voltage Fault
- Over-Current Fault
- Over-Temperature Fault
- EEPROM Fault
- Output Enabled
- Regulating
Configurations vary. We can provide any parameter you need.
- 06
Control electronics and modules
Monitor and control.
Through Argus and Cyclops, or Modbus TCP/RTU direct.
Typical parametersParameters are provided as per your device and its configuration.
Configurations vary. We can provide any parameter you need.
- 07
Any Modbus TCP/RTU device
Monitor and control.
Through Argus and Cyclops, or Modbus TCP/RTU direct.
Typical parametersParameters are provided as per your device and its configuration.
Configurations vary. We can provide any parameter you need.
Works with Diode Labs units and any Modbus TCP/RTU device.
02 / The signal
Field
Argus sits at the unit. It measures, and it carries out the commands you send.
Link
Real time over MQTT, Ethernet or Wi-Fi. Every one to five minutes over the Cyclops serial link. Modbus TCP and RTU devices connect directly.
Hermes
Stores every reading, judges protection against the โ850 mV criterion, and raises the alarm when a unit drifts.
People
Web and Windows desktop. Alarms by email, push, and SMS through your own SIMs.
Built on NACE criteria: the โ850 mV protection criterion and instant-off.
03 / Command
Send a command. Watch it land.
Set the DC output, switch a unit on or off, or run interruption cycles and read the instant-off potential. GPS-synchronized with the optional Argus GPS module.
- Pending
- Sending
- Awaiting acknowledgement
- Applied
Or Failed, with the reason.
Applied only when the unit confirms it, or a Modbus read-back matches the value you asked for.
- Limits are checked on the server, not in the browser.
- Only people with control permission, for that station, can send.
- Confirmation where the command requires it.
- Every command is written to the audit log.
04 / The console
This is the real console. Open it yourself.






Screenshot of the live demo, simulated data.
06 / Trust
Isolation, safe control and evidence.
Built to the OWASP Top 10 and the OWASP API Security Top 10.
- Isolation. Every customer gets their own database and credentials.
- Safe control. Server-side limits, scoped permission, and an audit record for every command.
- Evidence. An append-only audit log. Configuration changes are kept with the value they replaced.
Passwords are stored per the OWASP Password Storage Cheat Sheet: PBKDF2, at least 600,000 iterations.
Not yet certified. SOC 2 and ISO 27001 are planned.
Add-on Add-on, priced on request.
SourcesMOBILTEX CorView featuresBullhorn WebBullhorn wireless systemsElecsys Watchdog Scout XP datasheetElecsys Tracker datasheet
08 / Plans
Prices on the page.
Pick a Hermes Cloud plan, then size it to your fleet.
Iris
$229/mo billed monthly
10 units included ยท 10 users
Athena
$429/mo billed monthly
50 units included ยท 25 users
Olympus
$1,049/mo billed monthly
100 units included ยท Unlimited users
Self-managed, intranet and offline PC: scope agreed with you, priced on request.